| Model No. |
GP‐CVP036N‐12V‐P02 |
GP‐CVP036N‐24V‐P02 |
| Output |
DC Voltage Range |
12V |
24V |
| Rated Current |
0‐3A |
0‐1.5A |
| Rated Max. Power |
36W |
36W |
| Voltage Tolerance |
± 5% |
± 5% |
| Ripple & Noise (Max.) note.2 |
180 mVp‐p |
240 mVp‐p |
| Efficiency (Min) |
83% at 230VAC full load |
85% at 230VAC full load |
| Set up Time (Max) |
< 1S / 115VAC at full load / < 0.5S / 230VAC at full load |
| Input |
Rated Voltage |
100 ~ 240VAC 141 ~ 340VDC |
| Voltage Range |
90 ~ 264VAC |
| Frequency Range |
47 Hz ~ 63 Hz |
| AC Current (Max.) |
1A at 115VAC /0.5A at 230VAC |
| Inrush Current (Max.) |
< 30A at 115VAC /< 60A at 230VAC |
| Leakage Current |
< 0.25mA / 240VAC |
| No Load Consumption |
< 0.5W at 230VAC |
| Protections |
Over Current |
110% ‐ 150% Constant current limiting, auto‐recovery |
| Short Circuit |
Hiccup mode, recovers automatically after fault condition is removed |
| Over Temperature |
Shut down o/p voltage, recovers automatically after temperature goes down. |
| Over Voltage |
13‐18V |
29‐33V |
| Protection type: Shut down o/p voltage, recovers automatically after voltage goes down. |
| Environment |
Operation Temp. |
‐30°C ~ 40°C (Refer to output load derating curve) |
| Operation Humidity |
20% ~ 90% RH non‐condensing. |
| Storage Temp & Humidity |
‐30 ~ +80°C ,10% ~ 90% RH |
| Safety & EMC |
Safety Standards |
EN61347‐1,EN61347‐2‐13; |
| Withstand Voltage |
I/P ‐ O/P: 3.75K VAC |
| Isolation Resistance |
I/P ‐ O/P: 100M ohms / 500VDC at 25°C |
| EMI Conduction & radiation |
meet Compliance to EN55015; FCC PART15 CLASSB |
| EMS immunity |
meet Compliance to EN61000‐4‐2,3,4,5,6,11;EN61547,EN61000‐3‐2 CLASS C |
| Connection |
Input |
UL rated, 18 AWG x 2 C ( 150 mm) |
| Output |
UL rated, 18 AWG x 2 C ( 150 mm) |
| Others |
MTBF |
100K hours min. @Ta=25 °C |
| Dimension (L x W x H) |
110 x 35 x 25mm; 155g/pcs |
| Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C ambient temperature. 2. Ripple & Noise are measured at 20MHZ bandwidth oscilloscope and with 0.1uF & 47uF parallel capacitor. 3. The power supply is considered a component which will be installed a final equipment. The final equipment must be re‐confirmed that it still meets EMC directives. |