Caractéristques techniques :

  • Endurance : 105°C ▪ 2 000 heures
  • Optimisé pour les applications rentables
  • Gamme de capacité élevée
  • Large plage de tension, jusqu'à 500 V

Spécifications :

Items   Performance Characteristics
Operating Temperature Range   -40 ~ +105°C -25 ~ +105°C
Rated Voltage Range VR 6.3 ~ 100V DC 160 ~ 500V DC
Surge Voltage VS (VR  ≤ 315V):      VS  = 1.15∙VR (VR  > 315V):     VS  = 1.10∙VR
Capacitance Range CR 0.1 ~ 22000µF 0.47 ~ 560µF
Cap. Tolerance ΔC ±20% (120Hz ▪ 20°C)
Leakage Current (20°C ▪ VR  applied) ILEAK ≤ 0.01∙CR∙VR  or 3µA, whichever is
greater ▪ After 1 minute
≤ 0.03∙CR∙VR  or 3µA, whichever is
greater ▪ After 1 minute
[ ILEAK  (µA) ; CR  (µF) ; VR  (V) ]
Dissipation Factor % (20°C ▪ 120Hz) tanδ VR  (V DC) 6.3 10 16 25   35 50 63 100
tanδ (%) 22 17 16 14   12 10 9 8
VR  (V DC) 160 200 250 350   400 420 450 500
tanδ (%) 12 12 12 15   15 17 17 22
For CR  ≥ 1000μF, add 2% per every multiple 1000μF of rated capacitance value                  
Low Temperature Characteristics at 120Hz Z ratio max. VR  (V DC) 6.3 10 16 25   35 50 63 100
Z-25°C/Z+20°C 4 3 2 2   2 2 2 2
Z-40°C/Z+20°C 8 6 4 3   3 3 3 3
VR  (V DC) 160 200 250 350   400 420 450 500
Z-25°C/Z+20°C 2 2 3 5   6 6 6 6
For capacitance > 1000µF
Z-25°C/Z+20°C Add 0.5 for every multiple 1000µF of rated capacitance value
Z-40°C/Z+20°C Add 1 for every multiple 1000µF of rated capacitance value
Lifetime Test
Endurance 105°C
(VR & IR  applied)
Test 2000 hours
△C/CR ≤ ±20% of initial measured value
tanδ ≤ 200% of initial specified value
ILeak ≤ the initial specified value
Test 1000 hours
Shelf Life 105°C (VR = 0) △C/CR ≤ ±20% of initial measured value
tanδ ≤ 200% of initial specified value
ILeak ≤ the initial specified value
Before measurement: Restore capacitor to 20°C, apply VR  for 30 min according JIS-C-5101-4